10
10.5.4 TMS Control Registers
The TMS control registers are used to select TMS0/1 input events and the counter clock source, as
well as control counter startup. Following two TMS control registers are included:
• TMS0 Control Register (TMS0CR)
• TMS1 Control Register (TMS1CR)
TMS0 Control Register (TMS0CR)
D0
TMS0
SS0
D
Bit Name
0
TMS0SS0
(TMS0 measure 0 source selection)
1
TMS0SS1
(TMS0 measure 1 source selection)
2
TMS0SS2
(TMS0 measure 2 source selection)
3
TMS0SS3
(TMS0 measure 3 source selection)
4,5
TMS0CKS
(TMS0 clock source selection)
6
No functions assigned
7
TMS0CEN
(TMS0 count enable)
1
2
3
TMS0
TMS0
TMS0
SS1
SS2
SS3
10-143
MULTIJUNCTION TIMERS
10.5 TMS (Input-related 16-bit Timer)
<Address: H'0080 03CA>
4
5
6
TMS0CKS
Function
0: External input TIN15
1: Input event bus 0
0: External input TIN14
1: Input event bus 1
0: External input TIN13
1: Input event bus 2
0: External input TIN12
1: Input event bus 3
00: External input TCLK3
01: Clock bus 0
10: Clock bus 1
11: Clock bus 3
0: Count stops
1: Count starts
D7
TMS0CEN
<When reset:H'00>
R
W
0