Figure 4-31 Mts Lvd Kit Relay Connection Diagram - Motorola DIMETRA MTS 2 Installation, Configuration And Basic Service Manual

Hide thumbs Also See for DIMETRA MTS 2:
Table of Contents

Advertisement

MTS LVD Kit Installation

Figure 4-31 MTS LVD Kit Relay Connection Diagram

The number of LVD Kits used depends on the type of MTS:
Procedure 4-9 How to Install the MTS LVD Kit
1
2
4-32
For MTS2, only one LVD is necessary.
For MTS4 with two batteries, two LVD devices have to be used (one LVD for each PSU).
For MTS4 powered with a single battery, LVD battery cables should be connected in parallel.
LVD controller cables should be connected to separate PSUs so each PSU controls a LVD.
For MTS with XHUB configuration, see the first two points in this list.
Unpack the kit and check if all items are present.
Working on live system is hazardous, switch off power!
1. Connect the battery cables (Ø6 ring terminals apply) using a PH2 screwdriver.
Recommended torque is max 2Nm.
2. Two spare Ø6 terminals for 16 mm
these (not included).
3. Click the protection cap on. Additional break away windows are available on cap allowing
multiple entry of cables.
Make sure no damage are done on cables by sharp edges on the cap.
2
cable are included. Special crimp tool apply on fitting
Chapter 4: Hardware Installation
6802800U74-N September 2009