MTS 2 and MTS 4 Installation, Configuration and Basic Service Manual
Table 13-7 Generic Base Radio Alarms (Continued)
Alarm ID
ALM_EX_NVM_CKSUM_FAULT
ALM_EX_NVM_CKSUM_FAIL
ALM_TX_CLIP_DE-
TECT_ALM_FAULT
ALM_TX_CLIP_DETECT_FAULT
ALM_TX_CLIP_DE-
TECT_ALM_WARN
ALM_TX_CLIP_DETECT_WARN
ALM_TX_TEMP_INTER-
NAL_WARN
6802800U74-N September 2009
Recovery
Description
Action
Checksum
Software
fault for the
attempts to set
Exciter NVM
the parameters
parameters was
to the default
detected during
values taken
initialization
from the default
- some of
region in the
the Exciter
NVM memory.
configuration
parameters may
be corrupted.
The same as ALM_EX_NVM_CKSUM_FAULT
Reported when
BRC is de-keyed
Javelin clip
by the software.
detected failure
condition still
exists after 1
minute.
The same as ALM_TX_CLIP_DETECT_ALM_FAULT
Exciter Javelin
The output
clip detected.
power is reduced
by the software.
The same as ALM_TX_CLIP_DETECT_ALM_WARN
Internal Power
The output
Amplifier
power is reduced
temperature is
by the software.
too high.
Base Radio Alarms
Clear Action
If the operation
Corrupted
of restoring
configuration
defaults is
parameters may cause
successful the
that BRC works
alarm is cleared.
incorrectly. The
Otherwise the
default values may
alarm status is
be different than the
unchanged.
lost parameter values.
To make sure the
parameters can be
restored manually to
the earlier backed up
values.
BRC is re-keyed
The alarm may be
by the software.
reported because
If the alarm
of the BRC
condition
hardware failure
disappears after
or configuration
key-up then the
problems.
alarm is cleared.
If the alarm
is reported for
the third time it
cannot be cleared
until next BRC
reset.
If the alarm
The alarm may be
condition
reported because
disappears then
of the BRC
the output power
hardware failure
is restored by
or configuration
the software to
problems.
the target level.
If the alarm
is reported for
the third time it
cannot be cleared
until next reset.
If the alarm
condition
disappears then
the output power
is restored by the
software to the
target level.
Notes
13-27