RX Connection
•
•
Figure 4-42 RX Connection Between MTS 4 Prime Cabinet and MTS4 Expansion Cabinet
4-42
For Dual diversity, Filter 1 (far left) in the MTS 4 Prime Cabinet is connected
to the RX Splitter 1 in the Expansion Cabinet; Filter 2 (far right) is connected
to the RX Splitter 2 in the Expansion Cabinet.
For Triple diversity, Filter 1 (far left) in the MTS 4 Prime Cabinet is connected to the RX Splitter
1 in the Expansion Cabinet; Filter 2 (far right) is connected to the RX Splitter 2 in the Expansion
Cabinet; Filter 3 (in the middle) is connected to the RX Splitter 3 in the Expansion Cabinet.
Rx connection cables between the MTS 4 Prime Cabinet and the Expansion Cabinet are
routed on the outside of the cabinet, as shown in Figure below.
Chapter 4: Hardware Installation
6802800U74-N September 2009