Base Radio Alarms
Table 13-7 Generic Base Radio Alarms (Continued)
Alarm ID
ALM_RX_DC_INJ1_FAULT
ALM_RX_DC_INJ1_FAIL
ALM_RX_DC_INJ2_FAULT
ALM_RX_DC_INJ2_FAIL
ALM_RX_DC_INJ3_FAULT
ALM_RX_DC_INJ3_FAIL
ALM_RX_DC_INJ_FAIL
13-30
Recovery
Description
Action
Receiver
Branch1 of
branch1 LNA
Receiver is
DC injection
disabled by the
failure.
software - if no
more enabled
branches then
BRC is unable
to receive,
otherwise BRC
is still able to
receive but the
coverage can be
lower
The same as ALM_RX_DC_INJ1_FAULT
Receiver
Branch2 of
branch2 LNA
Receiver is
DC injection
disabled by the
failure.
software - if no
more enabled
branches then
BRC is unable
to receive,
otherwise BRC
is still able to
receive but the
coverage can be
lower
The same as ALM_RX_DC_INJ2_FAULT
Receiver
Branch3 of
branch3 LNA
Receiver is
DC injection
disabled by the
failure.
software - if no
more enabled
branches then
BRC is unable
to receive,
otherwise BRC
is still able to
receive but the
coverage can be
lower
The same as ALM_RX_DC_INJ3_FAULT
Reported when ALM_RX_DC_INJx_FAULT alarms for all Receiver branches
are set
Chapter 13: MTS Troubleshooting
Clear Action
If the alarm
The alarm may be
condition
reported because
disappears
of the BRC
then branch1
hardware failure
of Receiver is
or configuration
re-enabled by the
problems.
software.
If the alarm
The alarm may be
condition
reported because
disappears
of the BRC
then branch2
hardware failure
of Receiver is
or configuration
re-enabled by the
problems.
software.
If the alarm
The alarm may be
condition
reported because
disappears
of the BRC
then branch3
hardware failure
of Receiver is
or configuration
re-enabled by the
problems.
software.
6802800U74-N September 2009