MTS - Restoration Procedures

MTS - Restoration Procedures
The MTS Site Controller has the following modes of operation:

Table 8-7 MTS - Restoration Impact

Action
Replacing a Site
Controller
8-18
You must be familiar with Man-Machine Interface (MMI) commands and their
usage prior to performing procedures in this chapter. Improperly applying
MMI commands can result in equipment damage.
You must disable Black Ice or any other Firewall application before attempting to transfer
files.you must disable Black Ice or other Firewall application before attempting to transfer files
BOOT1 - to access this mode interrupt the booting process by pressing Escape
key or Control-C combination when appropriate message is shown. A
password may be required to enter this mode.
Test Application - to access this mode enter the testapp command when in
BOOT1 mode. To go back to normal Site Controller Application enter reset
-oplatform command to reboot and resume normal operation.
Site Controller Application - if the boot process is not interrupted, this
is the default mode of operation.
Site will be off air, radios have to find
service on other site.
Service Affected
If the site is a dual Site
Controller site, a switchover
of Site Controller would cause
outage of approximately 2
minutes. A switch back to the
newly replaced Site Controller
for testing could also introduce
outage of approximately 2
minutes.
Chapter 8: Site Controller
Service Downtime
Approximately one hour. Does
not include Ki'ing of site because
this depends on if the KVL has
to be driven back to the Switch
site where the AuC is located.
6802800U74-N September 2009