Configuring Redundant Site Controller - Motorola DIMETRA MTS 2 Installation, Configuration And Basic Service Manual

Hide thumbs Also See for DIMETRA MTS 2:
Table of Contents

Advertisement

Configuring Redundant Site Controller
Procedure 8-25 Add Additional Site CONTROLLER (Continued)
8
9
10
11
12
Configuring Redundant Site Controller
8-46
Connect the Ethernet cables previously attached to the Base Radio(s) to the Site Controller. Also
connect the newly added Site Controller to the junction panel according to the scheme below:
Part number
3066543B10
3066560B01
3066567B02
Connect RF cable 3066543B10 to GPS connector.
Connect the redundant control signal cable according to the scheme below:
Part number
3066544B17
3066544B17
Make sure to follow the color indications on both the cables as well as on the Site
CONTROLLER.
Remove the Terminator from the CAN2 output on the Power Supply Unit and connect the CAN
Bus cable according to the scheme below:
Part number
3066544B03
Connect the power cables to the MTS Power Supply Unit.
Redundant Site Controller feature is supported by MTS Software releases:
• MTS SPU R5.2_002.34 or later
• MTS SPU R6.0_001.12 or later
On power up of the Standby Site Controller the Base Radios may dekey and reset. Base
Radios will automatically recover and key up again within 20 seconds.
Cable type
RF Cable
Junction Panel /
E1
Y splitter
Y splitter
Cable type
Redundant
SC1 / RedIn
CTRL signal
cable
Redundant
SC1 / RedOut
CTRL signal
cable
Cable type
CAN Bus cable
SC2 / CAN
Chapter 8: Site Controller
From
To
Y splitter
SC1 / E1
SC2 / E1
From
To
SC2 / RedOut
SC2 / RedIn
From
To
PSU2 / CAN2
6802800U74-N September 2009