Procedure 11-2 How to Reinstall Power Supply Unit (Continued)
4
5
6

PSU TrackID Update

Procedure 11-3 How to Update the Mapping List with the New PSU TrackID
1
2
3
4
5
6
6802800U74-N September 2009
Connect remaining cables according to labels attached before PSU removal.
Switch ON the Power Supply Unit.
Check the LED indicators to verify the PSU is operating correctly.
Log in to the Site Controller.
Use the following MMI command to view the mapping list:can check_mapping
See example below:
SC> can check_mapping
Units are present:
Device Track ID
DPM 1 JTH0500101
DPM 2 JTH0500105
Units are not present:
PSU 1 JTH0500200
Track ID not mapped:
JTH0500102
On the list, locate the unit that you have removed and that is indicated as Units are not
present.
Delete old CAN Bus unit from the CAN Bus unit mapping list. Use can remove_mapping
<Device>, where <Device> is the old unit name. See example below:
SC> can remove_mapping psu 1
Add new CAN Bus unit to the CAN Bus unit mapping list.
The new unit Track ID is present on the replaced unit label and indicated as Track
ID not mapped in the list shown in
Use can add_mapping <Device> <TrackID>, where <TrackID> is a TrackID of
the new unit and <Device> is the new unit name: psu X, where X denotes a digit between 0
and 2). See example below:
SC> can add_mapping psu 1 JTH0500102
View the updated mapping list using the can check_mapping command and check that
there are no units labelled as Track ID not mapped or Units are not present.
PSU TrackID Update
step
2.
11-11