Motorola DIMETRA MTS 2 Installation, Configuration And Basic Service Manual page 395

Hide thumbs Also See for DIMETRA MTS 2:
Table of Contents

Advertisement

MTS 2 and MTS 4 Installation, Configuration and Basic Service Manual
Table 13-7 Generic Base Radio Alarms (Continued)
Alarm ID
ALM_TX_LVL_PWR_FAIL
ALM_PA_NVM_CKSUM_FAULT
ALM_PA_NVM_CKSUM_FAIL
ALM_TX_DEKEYED_FWD
_PWR_HIGH
ALM_PA_DEKEYED_POWER
_PRESENT
6802800U74-N September 2009
Recovery
Description
Action
The power
BRC is de-keyed
leveling
by the software.
procedure failed
to establish the
output power
at the requested
level.
Checksum fault
Software
for the Power
attempts to set
Amplifier NVM
the parameters
parameters was
to the default
detected during
values taken
initialization
from the default
- some of the
region in the
Power Amplifier
NVM memory.
configuration
parameters may
be corrupted.
The same as ALM_PA_NVM_CKSUM_FAULT
Reported if
BRC is de-keyed
Transmitter is
again by the
dekeyed and
software.
the forward
power meter still
measures some
output power
that exceeds
the configured
acceptable level.
The same as ALM_TX_DEKEYED_FWD_PWR_HIGH
Base Radio Alarms
Clear Action
The alarm is
The power leveling
cleared just after
is done periodically
BRC is de-keyed.
to make sure that
the output power
does not deviate
from the required
level. It is also done
each time when the
target output power is
changed by recovery
or clear actions of
some alarms.
If the operation
Corrupted
of restoring
configuration
defaults is
parameters may cause
successful the
that BRC works
alarm is cleared.
incorrectly. The
Otherwise the
default values may
alarm status is
be different than the
unchanged.
lost parameter values.
To make sure the
parameters can be
restored manually to
the earlier backed up
values.
The alarm may be
reported because of
some software error
or the BRC hardware
failure.
Notes
13-29