Procedure 15-5 How to Add Redundant Site Controller (Continued)
10
11
12
Configuring Redundant Site Controller
6802800U74-N September 2009
Connect the redundant control signal cable according to the scheme below:
Part no
3066544B17
3066544B17
Make sure to follow the color indications on both the cables as well as on the Site
CONTROLLER.
Remove the Terminator from the CAN2 output on the Power Supply Unit and connect the CAN
Bus cable according to the scheme below:
Part no
3066544B03
Connect the power cables to the MTS Power Supply Units.
Redundant Site Controller feature is supported by MTS Software releases:
• MTS SPU R5.2_002.34 or later
• MTS SPU R6.0_001.12 or later
On power up of the Standby Site Controller the Base Radios may dekey and reset. Base
Radios will automatically recover and key up again within 20 seconds.
Configuring Redundant Site Controller
Cable type
From
Redundant
SC1 / RedIn
CTRL signal
cable
Redundant
SC1 / RedOut
CTRL signal
cable
Cable type
From
CAN Bus cable
SC2 / CAN
To
SC2 / RedOut
SC2 / RedIn
To
PSU2 / CAN2
15-29