Motorola DIMETRA MTS 2 Installation, Configuration And Basic Service Manual page 461

Hide thumbs Also See for DIMETRA MTS 2:
Table of Contents

Advertisement

MTS 2 and MTS 4 Installation, Configuration and Basic Service Manual
Procedure 15-7 Site Controller Configuration Files (Continued)
6
7
8
In order for the Redundant Site Controller feature to work correctly, the Ethernet ports used
to connect the two Site Controllers need to be specifically configured. The correct IP adresses
for each Site Controller must be as specified below.
Site Controller 1 (SC1)
Site Controller 2 (SC2)
Procedure 15-8 Configure Ethernet Ports
1
2
3
4
5
6802800U74-N September 2009
Download the new configuration file to the InActive Bank (set to use as next after reset).
Reset the Site Controller.
Confirm the configuration is correct.
Remember to check the configuration of both Site Controllers.
eth0: 10.0.253.1
eth1: 10.0.254.1
eth0: 10.0.254.2
eth1: 10.0.253.2
Log onto Boot1 of the Site Controller during startup.
From the prompt, run the command spr inet/if/eth0.
From the prompt, run the command spr inet/if/eth1.
Take note of the IP addresses and the MAC addresses.
If the IP addresses are set correctly (as stated in lists prior to this procedure),
continue to Step 8 below.
If the IP addresses are set incorrectly, they must be changed as follows in the next
step.
Log onto Boot1 of the Site Controller.
Configuring Redundant Site Controller