Site Controller - Updating Can Bus Trackid Mapping List - Motorola DIMETRA MTS 2 Installation, Configuration And Basic Service Manual

Hide thumbs Also See for DIMETRA MTS 2:
Table of Contents

Advertisement

MTS 2 and MTS 4 Installation, Configuration and Basic Service Manual
Table 8-6 Site Controller - CAN Bus Functionality (Continued)
Unit
DPM (Duplexer,
Post Filter)

Site Controller - Updating CAN Bus TrackID Mapping List

Procedure 8-1 Site Controller - How to Update the Mapping List with the New Unit TrackID
1
2
3
4
6802800U74-N September 2009
Monitoring:
• Forward power on a digital power monitor: the input power range is from 0
W to 150 W.
• Reverse power on a digital power monitor: the input power range is from 0
W to 40 W.
• VSWR from a DPM.
• DPM temperature.
• DPM Heartbeat signal.
Alarms:
• SW is corrupted or unable to initialize.
• VSWR alarm.
Controls:
• VSWR Alarm Threshold: establishes a threshold for enabling a VSWR
Alarm. Valid threshold values are in the range 1.00 to 10.00 where 1.00 means
No VSWR and recommended values are 3.00 for UHF and 4.00 for 800 MHz.
Log in to the Site Controller.
Use the following MMI command to view the mapping list:can check_mapping
See example below:
SC> can check_mapping
Units are present:
Device Track ID
DPM 1 JTH0500101
PSU 1 JTH0500200
Units are not present:
DPM 2 JTH0500105
Track ID not mapped:
JTH0500102
On the list, locate the unit that you have removed and that is indicated as Units are not
present.
Delete old CAN Bus unit from the CAN Bus unit mapping list. Use can remove_mapping
<Device>, where <Device> is the old unit name. See example below:
SC> can remove_mapping dpm 2
Site Controller - Updating CAN Bus TrackID Mapping List
Function
8-13