Fujitsu AIRSTAGE J-II Design & Technical Manual page 337

Hide thumbs Also See for AIRSTAGE J-II:
Table of Contents

Advertisement

FUNCTIONS
No.
Item
Language setting
Indoor unit registration
1
Installation
Functions setting
Display switching
Display units
Monitor contents (icon display)
2
Monitor
Monitor contents (list display)
Error list
Special state
Control units
3
Control
Control contents
Detailed control contents
Date and time
Panel cleaning and correction
Group
4
Setting
Background light and beep
sound
Password
Schedule timer
Temperature range
Error history
Status history
5
Maintenance
Operation history
Version display
6
Others
External input/output
*1 : Product specifications are subject to change without notice.
 When Start/Stop, operation mode setting, room temp. setting, fan speed setting, air flow direction setting, swing
setting, economy mode, and anti freeze setting are changed frequently by using the central controller like System
Controller, Touch Panel Controller, etc. or from Building Management System (BMS) via BACnet
Network Convertor, the number of operations for each indoor unit must not exceed 7,500 times/year.
If the number of setting change exceeds the above specified number, the rewriting count limit of the non-volatile
memory (memory built into the air conditioner and used for recording settings) will be exceeded, and may cause
breakdown.
Description
Design considering multi-language correspondence. *1
Indoor unit registration. Max. 400 units.
(Set data can be written to and read from USB flash drive)
Temperature set point limitation, external input, central operation
on/off setting.
Icon display, list display
ALL, group, individual (remote control group)
Group name, operation, operation mode, set temperature, time,
errors, timer setting, filter sign
Group name, operation, operation mode, set temperature, airflow,
air direction, special operation, anti-freeze, time, errors, timer
setting, filter sign
Group name, remote control group name, address, error code
Display during special operation
ALL, group, individual (remote control group)
Operation, operation mode, set temperature, airflow,
RC Prohibition, filter sign reset
Air direction, energy saving, anti-freeze, test run
Time display switching, year/month/day display switching, system
clock setting, summer time
Select display area for panel cleaning.
User can select black screen on display.
Stages: Max. 3 stages Settable up to 400 groups.
(Set data can be written to and read from USB flash drive)
Backlighting off time and brightness setting, BEEP sound
operation setting
Management level: 3 kinds
Max. 30 items settable
Celsius/Fahrenheit switching, cooling, heating, and AUTO each
settable.
Recording of Max. 10 errors each for touch panel controller and
each unit (indoor unit, outdoor unit)
Recording of Max. 100 operations each for each indoor unit.
Writable to USB flash drive.
Recording of Max. 100 operations. Writable to USB flash drive.
Version display
Input: Batch operation/stop, emergency stop
Output: Operation monitoring, error
- (05 - 33) -
®
Gateway or via

Advertisement

Table of Contents
loading

Table of Contents