• Bit device setting
Set a number in a unit of 32 points at the start of the device.
The connection status for each input axis type is stored in the set devices as follows.
Offset
*1
"07" or later
"05" or earlier
+0
+0
+1
+1
to
to
+31
+31
+32
to
+63
+64
+32
+65
+33
to
to
+95
+63
+96
to
+127
+128
+64
+129
+65
to
to
+139
+75
+140
+76
to
to
+159
+95
*1 Operating system software version
8 AUXILIARY AND APPLIED FUNCTIONS
182
8.4 Multiple CPU Advanced Synchronous Control
Item
*1
Servo input axis connecting information Axis 1
Servo input axis connecting information Axis 2
to
Servo input axis connecting information Axis 32
Servo input axis connecting information Axis 33
to
Servo input axis connecting information Axis 64
Command generation axis connecting information Axis 1
Command generation axis connecting information Axis 2
to
Command generation axis connecting information Axis 32
Command generation axis connecting information Axis 33
to
Command generation axis connecting information Axis 64
Synchronous encoder axis connecting information Axis 1
Synchronous encoder axis connecting information Axis 2
to
Synchronous encoder axis connecting information Axis 12
Empty