Synchronous control system monitor data
Symbol
Setting item Setting details
St.380
Synchronous
The bit device turns ON
control
during synchronous control.
St.381
Synchronous
• The bit device turns ON
analysis
when the synchronous
complete
control analysis is
completed.
• The bit device turns OFF
when [Rq.380]
Synchronous control start
(R: M43440+n/Q:
M12000+n) turns OFF to
ON.
Starting method for synchronous control
Synchronous control can be started by turning "[Rq.380] Synchronous control start (R: M43440+n/Q: M12000+n)" from OFF
to ON after setting the parameters for synchronous control.
"[St.1040] Start accept flag (R: M30080+n/Q: M2001+n)" turns ON at the synchronous control start, and the parameters for
synchronous control are analyzed. "[St.380] Synchronous control (R: M40000+n/Q: M10880+n)" turns ON after completion of
analysis, and the synchronous control starts.
Start the input axis operation after confirming that "[St.380] Synchronous control (R: M40000+n/Q: M10880+n)" of the output
axis turns ON.
When "[St.381] Synchronous analysis complete (R: M40080+n/Q: M10912+n)" is ON at the synchronous
control start, "[St.381] Synchronous analysis complete (R: M40080+n/Q: M10912+n)" turns OFF by turning
"[Rq.380] Synchronous control start (R: M43440+n/Q: M12000+n)" OFF to ON. However, "[St.381]
Synchronous analysis complete (R: M40080+n/Q: M10912+n)" does not turn ON by the analysis completion
at the synchronous control start. ("[St.381] Synchronous analysis complete (R: M40080+n/Q: M10912+n)"
turns ON by the analysis completion at the synchronous control analysis mode start.)
Ending method for synchronous control
Synchronous control can be ended by turning "[Rq.380] Synchronous control start (R: M43440+n/Q: M12000+n)" from ON to
OFF after the input axis operation is stopped.
"[St.380] Synchronous control (R: M40000+n/Q: M10880+n)" turns OFF at the synchronous control end, and the "[St.1040]
Start accept flag (R: M30080+n/Q: M2001+n)" turns OFF at the output axis stop.
Synchronous control can also be ended by turning "[Rq.380] Synchronous control start (R: M43440+n/Q: M12000+n)" from
ON to OFF during the input axis operation. However, it is recommended to end the synchronous control after stopping the
input axis operation since the output axis stops immediately.
Refer to Stop Operation of Output Axis for the stop operation of output axis at the synchronous control end.(Page 25 Stop
Operation of Output Axis)
[Md.1008] Execute program No. (R: D32012+48n/Q: D12+20n)
This register stores the starting program No. at the servo program starting.
"FFEF" is stored in the "[Md.1008] Execute program No. (R: D32012+48n/Q: D12+20n)" when starting advanced synchronous
control.
Setting value
Refresh
Fetch
cycle
cycle
OFF: Normal
Operation
operation
cycle
ON: Synchronous
control
OFF: Synchronous
control
analysis not
completed
ON: Synchronous
control
analysis
completed
Default
Device No.
value
MELSEC
iQ-R Motion
device
assignment
M40000+n
M40080+n
2 STARTING UP THE SYSTEM
2.2 Starting/Ending for Synchronous Control
Q series
Motion
compatible
2
device
assignment
M10880+n
M10912+n
23