5.3.18

Performing a fan test

Notes on replacing a defective fan
After replacing a defective system fan or PSU containing a defective fan,
the fan error indicators will stay lit until the next fan test. By default, a fan
test is automatically started every 24 hours. The first automatic fan test
being performed after replacing a fan will turn off the fan error indicator.
If you want to start the fan test manually, you can do so by following the
description below:
Executing the fan test via the iRMC S6 web interface
▶ Log into the iRMC S6 web interface.
The System menu is displayed on default.
▶ Open the Cooling page.
▶ Expand the Cooling Devices group.
▶ Click Start Fan Test.
For more information on iRMC settings, see the iRMC user guides.
In case of maintenance done by Fujitsu engineers in Japan:
Executing the fan test via Chassis ID Prom Tool
Please follow the instructions provided separately.
5.3.19

Updating the golden image

5.3.19.1

Updating the golden image for iRMC S6 firmware

The golden image is part of the PFR (Platform Firmware Resiliency)
feature.
The PFR feature provides protection of firmware, detection of tampered
firmware and automatic recovery of firmware.
RX2540 M7
Upgrade and Maintenance Manual
Basic software procedures
117