Field Replaceable Unit
(FRU)
Tools:
Phillips PH2 / (+) No. 2 screw driver
Preliminary steps
"Locating the defective server" on page
▶ If applicable,
"Removing the front cover with lock" on page
"Shutting down the server" on page
"Disconnecting the power cord" on page
"Getting access to the component" on page
▶ Release all PCIe SSD modules and pull them out a few centimeters, see
"Removing 2.5-inch HDD/SSD modules" on page
The PCIe SSD modules need not to be removed. But if you want to
remove them nevertheless, check if all PCIe SSD modules are
uniquely identified so that you can reinsert them into their original
bays.
▶ Release all dummy modules and pull them out a few centimeters, see
"Removing a 2.5-inch HDD/SSD dummy module" on page
"Removing the fan cage" on page
Removing the defective 24x 2.5-inch HDD backplane and the switch
board
▶ Disconnect all cables from the switch board.
RX2540 M7
Hard disk drive (HDD) / solid state disk (SSD)
50.
76.
Upgrade and Maintenance Manual
Hardware: 15 minutes
47.
50.
55.
180.
49.
177.
199