"Updating the NIC configuration file in a Linux and VMware environment" on
page
106.
▶ If applicable, reconfigure your network settings in the operation system
according to the original configuration of the replaced expansion card.
Configuration of network settings should be performed by the customer, see
"Notes on network settings recovery" on page
▶ If applicable, restore LAN teaming configurations, see
upgrading LAN controllers" on page
▶ If applicable,
"Installing the front cover with lock" on page
When the system is powered on after a CPU has been replaced or
upgraded, the Global Error indicator will start flashing with the message
CPU has been changed.
This only indicates that the CPU configuration has been altered. There
is no technical problem.
Proceed as follows:
● Restart your server.
● As soon as the startup screen appears, press the [F2] function key to
enter the BIOS.
● If a password is assigned, enter the password and press [Enter].
● Select the Exit menu.
● Select Commit settings and Exit.
● Verify that the Global Error indicator stops flashing.
"Verifying the system time settings" on page
"Verifying system information backup or restore" on page
▶ Verify whether the iRMC recognizes each installed part.
▶ If applicable, activate TPM functionality in the system BIOS under Security
> TPM (Security Chip) Setting > Security Chip. For more information, see
the corresponding BIOS Setup Utility reference manual.
"Looking for MAC/WWN/GUID and SAS addresses" on page
"Resuming BitLocker functionality" on page
RX2540 M7
115.
Upgrade and Maintenance Manual
System board and components
513.
"After replacing or
71.
104.
96.
107.
109.
521