Toshiba DP120F Service Manual page 245

Plain paper facsimile
Hide thumbs Also See for DP120F:
Table of Contents

Advertisement

• 2UAD 9
Bit
7
Equalizer Value at MF Dialing:
6
00: 0 db
01: -4 db
10: -8 db
11: -12 db
5
DP Make/Brake:
4
000: 60/40 msec. (10 PPS)
3
001: 67/33 msec. (10 PPS)
010: 63/37 msec. (10 PPS)
011: 50/50 msec. (10 PPS)
100: Undefined
101: Undefined
110: Undefined
111: Undefined
2
MF Timing:
1
000: 80/80 msec.
0
001: 70/70 msec.
010: 70/150 msec.
011: 60/60 msec.
100: 80/100 msec.
101: 150/50 msec.
110: 150/240 msec.
111: Undefined