(16) Cover the Drum unit with a clean cloth to protect the drum from exposure to light.
(17) Place the Developer assembly over paper to protect the surface on which you are work-
ing.
(18) Use a cotton swab to clean the Mylar sheet of the Developer assembly.
(19) Use the Mylar scraper to scrape off the toner between the metering blade and the black
toner roller on the Developer assembly. The following figure shows how to clean the
metering blade.
DP120F/DP125F Preventive Maintenance
Mylar sheet
Fig.10-2-15
Fig.10-2-16
10-12
Cotton swab
Metering blade
Mylar scraper
March 2000 © TOSHIBA TEC
10-2-15
10-2-16