Set Maintenance Tasks - Siemens SINUMERIK 828D Operating Manual

Computerized numerical controller for machine tools
Hide thumbs Also See for SINUMERIK 828D:
Table of Contents

Advertisement

23.2

Set maintenance tasks

You can make the following changes in the list of maintenance tasks in the configuration
mode:
● Set up a maximum of 32 maintenance tasks with interval, initial warning and number of
warnings to be acknowledged
● Change the interval, time of the initial warning and the number of warnings to be output
● Delete a maintenance task
● Reset the times of the maintenance tasks
Acknowledging a maintenance task
You can acknowledge the maintenance tasks with the "Servicing performed" softkey.
Note
Protection level
You require protection level 1 (manufacturer) to set up and edit maintenance tasks.
Service Planner
Display
Pos
Maintenance task
Interval [h]
1. warning [h]
Number of warnings
Remaining time [h]
Status
Turning
Operating Manual, 01/2015, 6FC5398-8CP40-5BA2
Meaning
Position of the maintenance task in the PLC interface.
Name of the maintenance task.
Maximum time until next servicing in hours.
Time in hours at which an initial warning is displayed.
Number of warnings that can be acknowledged by the operator before
an alarm message is output for the last time.
Time until the interval expires in hours.
The remaining time cannot be edited.
Display of the current status of a maintenance task.
The maintenance task has been started.
The maintenance task is completed.
The maintenance task is deactivated, i.e. the time has been
stopped.
The status cannot be edited.
Service Planner (828D only)
23.2 Set maintenance tasks