Clear Spanning-Tree Counters; Commands In The Global Configuration Mode; Spanning-Tree - Siemens SIMATIC NET Configuration Manual

Industrial wireless lan to ieee 802.11n command line interface
Hide thumbs Also See for SIMATIC NET:
Table of Contents

Advertisement

6.3.2

clear spanning-tree counters

Description
With this command, you reset all the statistical counters of the spanning tree function at the
device and port level.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli>
Syntax
Call the command without parameters:
clear spanning-tree counters
Result
The spanning tree counters are reset.
6.3.3

Commands in the global configuration mode

Requirements for changing to this mode:
● MSTP is enabled
● Base bridge mode: 802.1Q VLAN Bridge
● Compatibility mode: MSTP
This section describes commands that you can call up in the Global configuration mode.
In Privileged EXEC mode, enter the
Commands relating to other topics that can be called in the Global configuration mode can
be found in the relevant sections.
You exit the Global configuration mode with the
Privileged EXEC mode again.
6.3.3.1

spanning-tree

Description
The Spanning Tree Protocol is used to monitor a LAN for redundant connections. These are
blocked and reactivated when necessary if there are changes to the network topology.
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
or
cli#
command to change to this mode.
configure terminal
or
end
exit
Network structures
6.3 Spanning Tree
command and are then in the
249

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance w720Scalance w760

Table of Contents