3.3

Reset and Defaults

This section describes commands for restarting the device and for restoring the original
configuration.
3.3.1

restart

Description
With this command, you restart the device.
Select one of the following configuration settings:
● Device restart with the current configuration
● Device restart with the factory configuration settings with the exception of the following
parameters:
– IP addresses
– Subnet mask
– IP address of the default gateway
– DHCP client ID
– DHCP
– System name
– System location
– System contact
– User names and passwords
– Mode of the device
● Device restart with the factory configuration settings.
Requirement
You are in the Privileged EXEC mode.
The command prompt is as follows:
cli#
Syntax
Call up the command with the following parameters:
restart[{memory|factory}]
The parameters have the following meaning:
● if no parameters are specified: restarts the system with the current configuration
Parameter
memory
factory
Result
The device is restarted with the selected settings.
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
Description
Resets the system to the factory configuration settings and restarts the system.
The parameters listed above are unaffected by a reset.
Resets the system to the factory configuration settings and restarts the system.
Configuration
3.3 Reset and Defaults
81