Siemens SIMATIC NET Configuration Manual page 418

Industrial wireless lan to ieee 802.11n command line interface
Hide thumbs Also See for SIMATIC NET:
Table of Contents

Advertisement

Security and authentication
10.2 WLAN
Syntax
Call up the command with the following parameters:
vap security authentication { show-methods | <methods> }
The parameters have the following meaning:
Parameter
show-
methods
methods
Result
The type of authentication is specified.
Further notes
You display the settings with the
418
Description
Lists the available types of
authentication
Value corresponding to an
authentication method.
show wlan security <vapX 0/Y>
Range of values / note
open-system
Without authentication. Encryption with a fixed (un-
changing) key can be selected as an option. To ena-
ble the key, use the "
command.
shared-key
A fixed key is stored for authentication.
wpa (Radius)
WPA authentication.
wpa-psk
WPA authentication without RADIUS server.
wpa2 (Radius)
WPA2 authentication.
wpa2-psk
WPA2 authentication without RADIUS server.
wpa-wpa2-auto (Radius)
WPA and WPA2 authentication
wpa-wpa2-auto-psk
WPA and WPA2 authentication without a RADIUS
server
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
vap security encryption
command.
"