7.4.2.4

snmp access

Description
With this command, you configure the access to an SNMP group.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
snmp access <GroupName>{v1|v2c|v3{auth|noauth|priv}}
[read <ReadView|none>][write <WriteView|none>][notify <NotifyView|none>]
[{volatile|nonvolatile}]
The parameters have the following meaning:
Parameter
GroupName
-
-
read
write
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
Description
Name of the group to which access is
configured
Selects the version of the protocol
used
Selects the authentication method:
the data can be read
Keyword
the data can be read and written
Keyword
Network protocols
7.4 SNMP
Range of values / note
max. 32 characters
v1
v2c
v3
auth
enables MD5 or SHA as au-
thentication method
noauth
no authentication
priv
enables authentication and
encryption
ReadView
none
WriteView
none