Severity - Siemens SIMATIC NET Configuration Manual

Industrial wireless lan to ieee 802.11n command line interface
Hide thumbs Also See for SIMATIC NET:
Table of Contents

Advertisement

11.1.6.9

severity

Description
With this command, you configure the threshold values for the sending of system event
notifications.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli (config-events) #
Syntax
Call up the command with the following parameters:
severity { mail | log | syslog | authlog } { info | warning | critical }
The parameters have the following meaning:
Parameter
mail
log
syslog
authlog
info
warning
critical
Result
The settings for sending system event messages are configured.
The "severity" function is enabled.
Further notes
You disable the setting with the
You display the status of this function and other information
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
Description
System event messages are sent by e-
mail.
System event messages are entered in
the log table.
System event messages are entered in
the syslog file.
System event messages are entered in
the log table for authentications.
System events are processed as of the
severity level "
Information
System events are processed as of the
severity level "
".
Warning
System events are processed as of the
severity level "
".
Critical
command.
no severity
Range of values / note
-
-
-
-
-
".
-
-
show events severity
Diagnostics
11.1 Diagnostics
451