Configuration
3.1 System
The parameter has the following meaning:
Parameter
longitude
Result
The longitude coordinate is created.
3.1.9.4

ethernetip

Description
With this command, you set whether EtherNet/IP will be enabled or disabled after the next
device restart.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
ethernetip {off|on}
The parameters have the following meaning:
Parameter
off
on
52
Description
Input box for the longitude coordinate
Description
EtherNet/IP will be disa-
bled after the next re-
start.
EtherNet/IP will be ena-
bled after the next re-
start.
Range of values / note
-
When EtherNet/IP is turned on, PNIO is turned off. The
switchover from EtherNet/IP and PNIO has no effect on
DCP.
If a PROFINET connection is established; in other words
the PNIO AR status is "Online", you cannot enable
EtherNet/IP.
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
Range of values / note
max. 32 characters
To use spaces in the entry, enter
the longitude coordinate in
quotes:
coordinates longitude
"123 456"