– "PROFIsafe configuration" - only for control via PROFIsafe
Safety Integrated
Function Manual, (FHS), 07/2016, 6SL3097-4AR00-0BP6
Click this button to open the "PROFIsafe Configuration" dialog box:
Enter the "PROFIsafe address" (p9610) of the drive in hexadecimal code here.
"Telegram configuration" (p60022) shows the currently parameterized PROFIsafe
telegram; "Safety parameterization" (p9611) shows the telegram currently used in the
Safety parameterization.
Click "Accept PROFIsafe telegram" to accept the currently parameterized PROFIsafe
telegram in the Safety parameterization.
Click "Close" to return to the "Safety Integrated" dialog box.
Commissioning
6.7 Commissioning: Basic procedure