Maintenance 6. Maintenance Parts Replacement Procedures

6.5 CF (Compact Flash)

CF Remove
(1) Turn OFF the Controller and unplug the power connector.
(2) Remove the CPU board unit.
(3) Pull out the CF in the direction shown
CF Mount
(1) Insert the new CF along the guide rail.
NOTE
(2) Mount the CPU board unit.
(3) Plug in the power connector. Turn ON the Controller and make sure that the
158
Refer : Maintenance 6.4 CPU Board Unit
by the arrow.
Insert the CF until the CF is approximately 3 mm out from the ETX module.
Refer : Maintenance 6.4 CPU Board Unit
Controller starts properly without any vibration or abnormal noise.
ETX
Module
CF
RC180 Rev.17