Board Setup (Rs-232C); Verify With Epson Rc+5.0 (Rs-232C) - Epson RC180 Manual

Robot controller
Hide thumbs Also See for RC180:
Table of Contents

Advertisement

Setup & Operation 12. Option Units

12.4.2 Board Setup (RS-232C)

Board Appearance
CN1
CN2
CN3
CN4
12.4.3 Verify with EPSON RC+ 5.0 (RS-232C)
When an RS-232C board is mounted in as option unit, the Controller software
automatically identifies the RS-232C board. Therefore, no software configuration is
needed. Correct identification can be confirmed from EPSON RC+ 5.0.
(1) Select the EPSON RC+ 5.0 menu-[Setup]-[Controller] to display the [Setup
(2) Select the [RS-232C].
If no RS-232C board is identified, RS-232C will not be displayed.
If RS-232C is displayed, then the Controller software identified the RS-232C board.
Communication with external equipment is available.
110
Controller] dialog.
Switch and Jumper Configuration
Set DSW1, DSW2 and JMP1.
CN6 is all open.
st
1
board
CN6
JMP1
DSW2
IRQ15
JP5
DSW1
IRQ11
JP4
IRQ10
JP3
IRQ7
JP2
IRQ5
JP1
1 2
SW4
SW3
SW2
SW1
SW8
SW7
SW6
SW5
SW4
SW3
SW2
SW1
nd
2
board
IRQ15
JP5
IRQ11
JP4
IRQ10
JP3
IRQ7
JP2
IRQ5
JP1
1 2
SW4
SW3
SW2
SW1
SW8
SW7
SW6
SW5
SW4
SW3
SW2
SW1
RC180 Rev.17

Hide quick links:

Advertisement

Table of Contents
loading