12.3.9 Operation (DeviceNet, PROFIBUS-DP, EtherNet/IP,
This section indicates how to use the Fieldbus I/O option after it has been installed.
For details of CC-Link, also refer to 12.3.5 CC-Link – Operation (CC-Link).
SPEL+ Fieldbus I/O Commands
All the commands for the Fieldbus I/O are the same as the standard I/O.
Bit numbers differ from standard I/O. There is no restriction for command use.
Typical I/O commands are listed in the following table.
For command details, refer to EPSON RC+ 5.0 Online Help or SPEL
Reference.
Command
In
InW
Off
On
Out
OutW
Sw
Wait
NOTE
Response times for Fieldbus I/O can vary and depend on several factors, including baud
rate, scan rate, number and types of devices, communication error, etc.
Outputs Off by Emergency Stop and Reset Instruction
You can configure the controller system so that all outputs including the fieldbus outputs
will be turned off when the emergency stop occurs and when a Reset instruction is
executed.
For details of the configuration, refer to [Setup]-[Controller]-[Preference] in EPSON RC+
5.0 User's Guide 5.12.2 Controller command (Setup Menu).
A command that was issued just before an emergency stop can be executed after the
NOTE
emergency stop condition is cleared. If the outputs from the fieldbus involve risk, check
the [Outputs off during Emergency Stop] box to remove all power to output devices when
an emergency stop occurs.
Remote I/O Configuration
You can configure the controller system so that all I/O including the fieldbus will be set to
remote function.
I/O setup for Fieldbus I/O is the default configuration.
NOTE
Setup for the Remote I/O can be changed by signal. Configuration with bits of standard
I/O, expansion I/O and Fieldbus I/O is available.
RC180 Rev.17
PROFINET)
Returns the status of the specified 8 bits input port.
Returns the status of the specified 16 bits input port.
Turns Off the specified output.
Turns On the specified output.
Simultaneously sets 8 output bits.
Simultaneously sets 16 output bits.
Returns the specified input port status.
Waits until the specified input condition.
Setup & Operation 12. Option Units
Function
+
Language
107