Maintenance 6. Maintenance Parts Replacement Procedures
6.7.6 Mount Option Units 1 & 2
(1) Secure Option Units 1 and 2 with two screws each on front and backside.
(2) Connect the flat cable connector to the backside
(3) Secure the backside covers of Option Unit 1 with two screws for each.
(4) Plug in the power connector. Turn ON the Controller and make sure that the
166
of Option Unit 1.
Controller starts properly without any vibration or abnormal noise.
Option Unit 1
Back of Controller
Main Chassis
Connecting Connector
RC180 Rev.17