Maintenance 6. Maintenance Parts Replacement Procedures
6.7.2 Mount Option Unit 1
(1) Secure Option Unit 1 with two screws each on front side and backside.
(2) Connect the flat cable connector to the backside of
(3) Secure the backside cover to Option Unit 1 with two screws.
(4) Plug in the power connector. Turn ON the Controller and make sure that the
6.7.3 Remove Option Unit 2
(1) Turn OFF the Controller and unplug the power connector.
(2) Disconnect the cables connected to the Option Unit board.
(3) Remove two screws on each unit from the
(4) Pull out the flat cable connector connected on the
NOTE
162
Option Unit 1.
Orient the cover so that there is no gap when mounted.
Controller starts properly without any vibration or abnormal noise.
backside of Option Units 1 and 2 to remove the
covers.
backside of Option Units 1 and 2.
Compress both ends of the connector to pull out
the connector.
Option Unit 1
Back of Controller
Main Chassis
Connecting Connector
RC180 Rev.17