Maintenance 8. Trouble Shooting
No.
Message
I/O input/output byte number is out of
2345
available range or the board is not
installed.
I/O input/output word No. is out of
2346
available range or the board is not
installed.
Memory I/O bit number is out of
2347
available range.
Memory I/O byte number is out of
2348
available range.
Memory I/O word number is out of
2349
available range.
Command allowed only when virtual
2350
I/O mode is active.
Cannot change the status for CC-Link
2351
system area.
Remote setup error.
2352
CC-Link
system area
function.
File failure. Failed to open the
2360
configuration file.
File failure. Failed to close the
2361
configuration file.
File failure. Failed to open the key of
2362
the configuration file.
File failure. Failed to obtain the string
2363
from the configuration file.
File failure. Failed to write in the
2364
configuration file.
File failure. Failed to update the
2365
configuration file.
The string combination exceeds the
2370
maximum string length.
2371
String length is out of range.
Invalid character is specified after the
2372
ampersand in the Val function.
Illegal string specified for the Val
2373
function.
String Failure. Invalid character code
2374
in the string.
Cannot use ' 0 ' for Step value in
2380
For...Next.
Relation
between
2381
GoSub is invalid. Going in or out of a
For...Next using a Goto statement.
Cannot execute Return while executing
2382
OnErr.
Return was used without GoSub.
2383
Review the program.
Case or Send was used without Select.
2384
Review the program.
194
Review the program.
Check whether the expansion I/O board
and Fieldbus I/O board are correctly
detected.
Review the program.
Check whether the expansion I/O board
and Fieldbus I/O board are correctly
detected.
Review the program.
Review the program.
Review the program.
The command can be executed only for
virtual I/O mode.
Cannot assign
to
remote
Restore the controller configuration.
Restore the controller configuration.
Restore the controller configuration.
Restore the controller configuration.
Restore the controller configuration.
Restore the controller configuration.
The maximum string length is 255.
Review the program.
The maximum string length is 255.
Review the program.
Review the program.
Review the program.
Review the program.
Check the Step value.
For...Next
and
Review the program.
Review the program.
Review the program.
Review the program.
Remedy
Note 1
Note 2
Byte number
Word number
Bit number
Byte number
Word number
Combined
string length