Refitting
Use the following procedure to refit the system power supply.
1
3HAC035738-001 Revision: E
Action
Disconnect all connectors from the unit.
Loosen the two upper attachment screws.
Remove the two lower attachment screws.
Pull the power supply unit outwards and then
downwards to release it from the upper screw
heads, and remove it.
Action
DANGER
Before commencing any work inside the cabinet,
please observe the safety information in section
DANGER - Make sure that the main power has been
switched off! on page
29.
© Copyright 2009-2013 ABB. All rights reserved.
4.16.2 Replacement of system power supply
Note/Illustration
xx0900000570
A: upper attachment
screws
B: lower attachment screws
Note/Illustration
Continues on next page
4 Repair
Continued
A
B