ABB IRC5 Compact Product Manual page 99

Hide thumbs Also See for IRC5 Compact:
Table of Contents

Advertisement

2
3
4
5
6
7
8
3HAC035738-001 Revision: E
Action
xx0200000023
WARNING!
The unit is sensitive to ESD. Before handling the
unit please read the safety information in the sec-
tion
WARNING - The unit is sensitive to ESD! on
page 30
Remove the top cover of the cabinet.
Remove the left side cover of the cabinet.
Remove the 2 attachment screws, and pull the
safety board unit (board and plate) out a little bit.
Disconnect all connectors.
Remove the eight attachment screws.
Gently lift the safety board out.
© Copyright 2009-2013 ABB. All rights reserved.
4 Repair
4.2 Replacement of safety board
Note/illustration
See
Removing the top cover on
page
67.
See
Removing the left side cover
on page
67.
A
xx0900000323
A: Attachment screws
Make a note of all connections.
xx0900000566
Continues on next page
Continued
99

Hide quick links:

Advertisement

Table of Contents
loading