Operation
6.9 Communication over CANopen
6.9.2.2

Free objects

You can interconnect any process data objects of the receive and transmit buffer using
receive and transmit double words.
Scaling the process data of the free objects:
● 16-bit (word): 4000 hex ≙ 100%
● 32-bit (doubleword) 4000000 hex ≙ 100%
● For temperature values: 16-bit (word): 4000 hex ≙ 100° C
● For temperature values: 32-bit (doubleword): 4000000 hex ≙ 100° C
The "SINAMICS parameters" column shows the parameter numbers assigned in the inverter.
The assignment applies to the case in which an object which is not mapped in any PDO is to
be accessed via SDO.
OD index (hex) Description
5800 ... 580F
16 freely-interconnectable receive process
data
5810 ... 581F
16 freely-interconnectable transmit process
data
5820 ... 5827
8 freely-interconnectable receive process data
5828 ... 582F
Reserved
5830 ... 5837
8 freely-interconnectable transmit process data I32
5828 ... 582F
Reserved
6.9.2.3

Objects from the CiA 402 drive profile

The following table lists the object directory with the index of the individual objects for the
drives. The "SINAMICS parameters" column shows the parameter numbers assigned in the
inverter.
OD index
Sub-
Name of the object
(hex)
index
(hex)
Predefinitions
67FF
Single device type
Common entries in the object dictionary
6007
Abort connection option code
6502
Supported drive modes
6504
Drive manufacturer
Device control
6040
Controlword
6041
Status word
286
Data
Default val-
type per
ues
PZD
I16
0
I16
0
I32
0
0
SINAMICS
Trans-
Data
parameters
mission
type
SDO
U32
p8641
SDO
I16
SDO
I32
SDO
String
r8795
PDO/
U16
SDO
r8784
PDO/
U16
SDO
Operating Instructions, 12/2014, A5E32923362A
Can be read/
SINAMICS
written
parameters
r/w
r8745[0 ... 15]
r
r8746[0 ... 15]
r/w
r8747[0 ... 7]
r
r8748[0 ... 7]
Default
Can be
setting
read/
written
r
3
r/w
r
SIEMENS r
r/w
r
Inverter cabinet units