Terminal Module Tm150 - Siemens SINAMICS S120 Commissioning Manual

With startdrive
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Diagnostics
5.2 Diagnostics using LEDs
5.2.4.5

Terminal Module TM150

Table 5- 32
Meaning of the LEDs at the Terminal Module TM150
LED
Color
Green
Orange
READY
Red
Green/
Red
Green/
orange
or
red/
orange
260
State
Description, cause
Off
Electronic power supply is missing or outside permissible
tolerance range.
Continu-
The component is ready for operation and cyclic DRIVE-
ous light
CLiQ communication is taking place.
Continu-
DRIVE-CLiQ communication is being established.
ous light
This component has at least one fault.
Continu-
Remark:
ous light
LED is controlled irrespective of the corresponding messag-
es being reconfigured.
Flashing
Firmware is being downloaded.
light
0.5 Hz
Flashing
Firmware has been downloaded.
light
Wait for POWER ON.
2 Hz
Component recognition via LED is activated (p0154).
Flashing
Remark:
light
Both options depend on the LED status when module
2 Hz
recognition is activated via p0154 = 1.
Commissioning with Startdrive
Commissioning Manual, 12/2018, 6SL3097-5AA10-0BP0
Remedy
Check power supply
Remedy and
acknowledge fault
Carry out a POWER
ON