Diagnostics
5.3 Diagnostics via Startdrive
Configuring recording conditions
Select the required trigger condition in the "trigger mode" field in the drop-down list.
Figure 5-7
Configuring the recording conditions depends on the selected trigger condition:
Trigger condition: Start recording immediately
1. Enter the recording time under "Recording duration". The maximum possible recording
duration is displayed to the right.
Should you wish to set the maximum recording time, activate the option "Use max.
recording duration".
2. Enter a recording cycle under "Cycle" The possible cycle settings depend on the number
of signals.
Trigger condition: Trigger on variable
1. Select a trigger parameter from the "Trigger variable" field. The following options are
available:
– Click on the icon
– Enter the name or the parameter number into the input field for the trigger parameter.
Additional specific setting options are shown in accordance with the data type of the
selected trigger variables. If a trigger variable of the FLOAT data type was selected, for
example, a drop-down menu, a diagram and an entry field for a threshold value appear.
The following settings can be selected in the drop-down list for the "result":
272
Configuring trace recording conditions
for the trigger parameter and select a parameter.
Commissioning with Startdrive
Commissioning Manual, 12/2018, 6SL3097-5AA10-0BP0

Hide quick links: