Assignment of measuring system to Sensor Modules
Measuring systems
Resolver
Incremental encoder
sin/cos (1Vpp)
with zero pulse
Incremental encoder
sin/cos (1Vpp)
without zero pulse
EnDat absolute encoder
Incremental Encoder
TTL/HTL
SSI absolute encoder
2)
Temperature evaluation
Only for direct measuring systems.
1)
Only starting at article number 6SL3055-0AA00-5CA1.
2)
Protective separation.
3)
Additional information
You can find additional information about the Sensor Modules in the "Control Units and
Additional System Components" Manual and in the Startdrive online help.
4.4.8.5

Making detailed settings

You can configure the following encoder details for measuring systems during
commissioning:
● Actual value processing
● Encoder details such as encoder type, incremental tracks, gear ratio, etc.
Procedure
1. Select the encoder in the device view and open the Inspector window.
2. In the Inspector window, select the "Measuring system details" menu.
Commissioning with Startdrive
Commissioning Manual, 12/2018, 6SL3097-5AA10-0BP0
SMC
SMC10
SMC20
SMC30
x
-
-
x
-
x
-
x
-
-
-
-
x
x
4.4 Creating a project offline in Startdrive
SMC40
SME20
1)
-
-
-
-
-
x
-
-
x
-
x
-
x
-
-
x
-
-
x
-
-
Commissioning
SME
SME25
SME120
SME125
-
-
x
x
x
x
-
-
-
x
3)
x
x
x
3)
121