4.11.3.4

Closing the brake

Parameterizing the "Close brake" command
To assign the parameters that influence the closing of the brake, proceed as follows:
Figure 4-80
1. Interconnect the signal sinks for the following options of the "Close brake at standstill"
function:
– p1224[0]: Close brake at standstill signal, inversion via p1275.2
– p1224[1]: Close brake at standstill signal, inversion via p1275.3
– p1224[2]: Close brake at standstill signal
– p1224[3]: Close brake at standstill signal
These four signals form an OR operation.
Commissioning with Startdrive
Commissioning Manual, 12/2018, 6SL3097-5AA10-0BP0
"Drive axis > Parameter > Drive functions > Brake control > Close brake"
Extended brake control: Close brake
Commissioning
4.11 Configuring brake control