Diagnostics
5.3 Diagnostics via Startdrive
The infeed unit / drive axis does not change into the "Operation" state until all the enable
signals are available. In the "Missing enables" screen form, the LEDs in the function view
indicate which enables are still missing.
5.3.4.2
Displaying control/status words
☐
The control and status words are displayed in the function view in 2 adjacent lists for
diagnostic purposes in the "Control/status words" screen form.
Selecting a group of control and status words
1. In one of the 2 drop-down lists, select the required group of control and status words.
The corresponding display and interconnection fields are displayed on the side of the
screen form on which you made the setting in the drop-down list.
An illuminated LED display means that the appropriate bit of the control or status word is
set.
2. If you want to display the values of several groups next to one another, set the other
desired groups in the other two drop-down lists
5.3.4.3
Status parameters
☐
The status parameters with the associated numeric values are displayed in the function view
in the "Status parameters" screen form:
Column
Number
Parameter text
Value
Unit
282
"Drive axis > Diagnostics > Control/status words"
"Drive axis > Diagnostics > Status parameters"
Meaning of the instruction
Number of the parameter
Complete parameter text in the long form
Numerical value of the parameter
Unit of the parameter
Commissioning with Startdrive
Commissioning Manual, 12/2018, 6SL3097-5AA10-0BP0