(1) An operation error will occur if:
• The (S1) data is outside the range of 1 to 8.
• The (S2) data is outside the range of 1 to 32767.
• The vision system specified with (S1) has not been logged on.
• The vision system parameter setting (Refer to APPENDIX 3.2.) is different from
the setting on the vision system.
• The tag specified with reading value cell or the spreadsheet data is not an
integer value.
• The current process is not completed when the specified timeout time has
elapsed.
(1) Program which issues a trigger to the vision system (camera) 1
MVTRG K1