Mitsubishi Electric Melsec Q Series Programming Manual page 543

Motion controller (sv13/sv22)
Hide thumbs Also See for Melsec Q Series:
Table of Contents

Advertisement

APPENDICES
POINT
The vision program status storage device value is refreshed at the following timing.
(1) When a job is loaded by the MVLOAD instruction or MVPST instruction.
(Refreshed immediately after loading.)
(2) When the vision system's online/offline status changes.
(3) When a job is loaded from a source other than the Motion CPU (In-Sight
Explorer, etc.). (Refreshed several seconds after loading.)
(4) When job is loaded and an online vision system is logged onto with the
MVOPEN instruction. (Refreshed several seconds after logging on.)
(e) Read Value Cell/Read Value Storage Device
Set this to store the vision system tag or numeric data of spreadsheet in the
Motion CPU device.
This does not need to be set if the numeric data does not need to be
referred to.
POINT
(1) The vision system image data can be stored in the image data storage device
by setting the format output string setting of TCP/IP protocol.
(2) When the data stored in the set tag or spreadsheet cell is not an integer value,
the value after truncation of decimal point is stored in the read value storage
device.
(3) If a spreadsheet cell is designated when using the vision system In-Sight
series, an error will occur when the job is executed.
The tag or spreadsheet cell is set in the Read Value Cell.
Setting with tag
Setting with cell
The word device storing the value set in the tag or spreadsheet cell is set in
the read value storage device.
Settable word devices are shown below.
Item
Data register
Link register
Motion register
(Note-1): Only the user device range can be set.
POINT
Set the device No. as an even-number.
The cell or tag value is stored as a 32-bit integer value in two successive
points of the set device.
Write the symbolic tag name in the original state.
(Example) Tag: Job.Pass_count → Set "Job.Pass_count".
Write the spreadsheet row (A to Z) and line (0 to 399).
(Example) Cell: A5 → Set "A5".
Device No. setting range
D0 to D8190
W0 to W1FFE
#0 to #7998
APP - 52
(Note-1)
EZ