Advertisement

5 OPERATION CONTROL PROGRAMS
[Errors]
[Program examples]
(1) An operation error will occur if:
• The (S1) data is outside the range of 1 to 8.
• The number of character string of spreadsheet cell or tag specified with (S2)
outside the range of 1 to 32 bytes.
• The spreadsheet cell or tag specified with (S2) does not exist.
• The data type of spreadsheet cell or tag specified with (S2) is different from
data format specified with (S3).
• The (S3) data is outside the range.
• The (S4) data is outside the range of 1 to 32767.
• The vision system specified with (S1) has not been logged on.
• The vision system parameter setting (Refer to APPENDIX 3.2.) is different from
the setting on the vision system.
• The reading data is not completed when the specified timeout time has elapsed.
(1) Program which transfers the floating-point value stored in D3000F to the tag
"Calib_1.World_Point0.X" of the vision system (camera) 1
MVOUT K1, "Calib_1.World_Point0.X", D3000F
5 - 139