E&M Tie Line Timer - NEC Electra Elite IPK II Programming Manual

Hide thumbs Also See for Electra Elite IPK II:
Table of Contents

Advertisement

Document Revision 1
Level:
IN
Description
Use Program 34-07 : E&M Tie Line Timer to define the system service tone timers.
Feature Cross Reference
J
2 - 332
Input Data
Item
No.
01
ODT/SRT Mark Method
02
ODT/SRT Wink Start Method
03
1st Digit Pause (LDT)
Leased Line Guard (LDT)
04
05
Trunk Answer Detect Timer for E&M / E1
Conditions
None
Tie Lines
Program 34 : Tie Line Setup
34-07 : E&M Tie Line Timer
Item
Electra Elite IPK II
Input Data
Default
0~64800
3
0~64800
0
0~64800
3
0~64800
0
0~64800
30