System Alarm Setup - NEC Electra Elite IPK II Programming Manual

Hide thumbs Also See for Electra Elite IPK II:
Table of Contents

Advertisement

Electra Elite IPK II
Level:
IN
Description
Use Program 90-10 : System Alarm Setup to assign a status to system alarms. You
can designate an alarm as Major or Minor. This program also assigns whether or not
the alarm is displayed to a multiline terminal and whether or not the alarm information
is reported to the pre-defined destination.
Input Data
Default
Alarm
Electra Elite IPK II Programming Manual
Program 90 : Maintenance Program
Alarm Number
Item
No.
01
02
TYPE
Report
1
2 (Minor)
0
2
2 (MIN)
0

90-10 : System Alarm Setup

Item
Input Data
Alarm Type
0 = Not Set
1 = Major Alarm
2 = Minor Alarm
Report
0 = Not Report (No autodial)
1 = Report (autodial)
Note
Board Initialization
Initialization failure or
Error
the ETU is defective.
Board Initial Test
ETU initial test failure
Error
or the ETU is defective.
Document Revision 1
001~100
Is Used To
Advise of . . .
Remove and reinstall
the ETU. If RECover
message is received
in the alarm report,
the ETU is good. If
not, replace with a
new ETU.
Remove and reinstall
the ETU. If RECover
message is received
in the alarm report,
the ETU is good. If
not, replace with a
new ETU.
Action
2 - 547