Tie Line Initial Setup - NEC Electra Elite IPK II Programming Manual

Hide thumbs Also See for Electra Elite IPK II:
Table of Contents

Advertisement

Electra Elite IPK II
Program 81 : Basic Hardware Setup for Trunk
Level:
IN
Description
Use Program 81-11 : Tie Line Initial Setup to define the various initial data for DID/
TLI/DTI packages.
Input Data
Item
No.
01
02
03
04
05
Electra Elite IPK II Programming Manual
Trunk No.
Item
DP Interdigit Time Selection
The DP Interdigit Time is the minimum
pause time between dial pulses. Use this
Program to select either Pattern A or pattern
B.
Prepause Time Selection
Specifies the loop open time for a hookflash
signal sent to the Tie Line when the Recall
key on a multiline terminal is pressed. A
Single Line Telephone (SLT) generates a
hookflash to the Tie Line when a SLT
hookflash is assigned.
Tie Line Answer Detect Time Selection
Specifies the time before an IPK II system
answer (Off-Hook) is recognized as an
answer.
Tie Line Release Detect Time Selection
Specifies the circuit disconnect detected on
the Tie Line on the distant system side is
recognized as Tie Line.
Incoming Signal Detect Time Selection
Specifies the time after the incoming signal
from another system is detected before the
acknowledge signal is sent out.

81-11 : Tie Line Initial Setup

1~ 200
Input Data
0 = Pattern A
(Pattern A: 10pps - 650 ms,
20pps - 500 ms)
1 = Pattern B
(Pattern B: 10pps - 800 ms,
20pps - 800 ms)
1~4
(1~4 = 0.5~2.0 seconds)
(5~15 = 3.0~13 seconds)
(0 = No Setting)
0~15
(130 ms~1950 ms)
(0 = No Setting)
0~15
(130 ms~1950 ms)
(0 = No Setting)
[Wink Start]
1~15
(130 ms~1950 ms)
(0 = No Setting)
[Delay]
1~15
(30 ms~450 ms)
(0 = No Setting)
Document Revision 1
Default
1
9
(600 ms)
4
(520 ms)
4
(520 ms)
[Wink Start]
3
(390 ms)
[Delay]
3
(90 ms)