Incoming Call Trunk Setup - NEC Electra Elite IPK II Programming Manual

Hide thumbs Also See for Electra Elite IPK II:
Table of Contents

Advertisement

Electra Elite IPK II
Level:
IN
Description
Use Program 22-02 : Incoming Call Trunk Setup to assign the incoming trunk type
for each trunk. There is one item for each Night Service Mode.
Input Data
Item
No.
01
Feature Cross Reference
J
Electra Elite IPK II Programming Manual
Program 22 : Incoming Call Setup
Trunk Port Number
Day/Night
Incoming Type
Mode
1~8
0
= Normal
1
= VRS (second
2
= DISA
3
= DID
4
= DIL
5
= E&M Tie line
6
= Delayed VRS
7
= ANI/DNIS
8
= DID(DDI) Mode
Conditions
When connecting to T1 trunks, after changing Program 22-02-01 to match the
H
Telco's connected T1 service type, the T1 cable or the T1 PCB must be
unplugged and then reconnected in order for the T1 PCB to sync.
When the trunk type is set to a 3 (DID), the DID Transfert Destination in 22-11-04
H
for each DID feature is not supported. This feature is only supported for DID
trunks when assigned as VRS.
Central Office Calls, Answering

22-02 : Incoming Call Trunk Setup

Default
0
dial tone if no
VRS installed)
Switching
Document Revision 1
001~200
Description
Use this option to set the
feature type for the trunk
you are programming.
Related
Program
14-04
2 - 227

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents