Default value
Item
Item
No
01
Detect Level
02
Start delay time
03
Min. detect level
04
Max. detect level
05
Forward twist level
06
Backward twist level
07
ON detect time
08
OFF detect time
Feature Cross Reference
None
Electra Elite IPK II Programming Manual
Type 1
0
0
10 (-20dBm)
2 (-2dBm)
5 (6dBm)
0 (1dBm)
1 (30ms)
1 (30ms)
Conditions
None
Type 2
Type 3
0
0
0
0
15 (-25dBm)
10 (-20dBm)
2 (-2dBm)
2 (-2dBm)
5 (6dBm)
5 (6dBm)
0 (1dBm)
0 (1dBm)
1 (30ms)
1 (30ms)
1 (30ms)
1 (30ms)
Document Revision 1
Type 4
Type 5
0
0
0
0
10 (-20dBm)
10 (-20dBm)
2 (-2dBm)
2 (-2dBm)
5 (6dBm)
5 (6dBm)
0 (1dBm)
0 (1dBm)
1 (30ms)
1 (30ms)
1 (30ms)
1 (30ms)